Description
VFD-CP2000 series inverters
The VFD-CP2000 series of frequency converters is designed to control pumps, fans, blowers and HVAC. It has a built-in PID controller with feedback from the analog input and built-in functions that allow you to control multi-pump systems, which reduces the costs of the entire application. Modular design, removable panel and built-in PLC controller allow for easy adaptation of individual needs.
PARAMETERS:
- Control: scalar (U / F), sensorless vector (SVC)
- Overload: 230V / 460V 120% for a minute (Light work)
- 120% for a minute, 160% for 3 seconds (Normal Operation)
- Built-in BACnet and MODBUS communication with RS-485 interface
- Additional protection of the PCB board ensures high durability in difficult industrial conditions
- Fire mode and bypass mode ensure operation of smoke exhaust in the event of a fire or other emergency
- Built-in control modes for pump / fan applications, PID control, sleep / wake up functions, in-flight frequency search and frequency jump function
- Easy-to-use LCD text panel and TP editor software that allows users to edit the displayed information themselves
- Built-in multi-pump application control system to control up to 8 motors
- Built-in PLC controller (10k memory steps) and real time clock
- Optional communication cards: PROFIBUS DP, DeviceNet, MODBUS TCP, EtherNet / IP and CANopen
- Expandable with an additional input / output card
EXTENSIONS:
I / O expansion cards
EMC-R6AA
- I / O expansion card 6 relay outputs
- the ability to assign functions to outputs depending on the inverter settings
- resistive load 5 A NO 250 VAC / 5A NO 30 VDC
- inductive load 2 A NO 250 VAC / 2 A NO 30 VDC
EMC-D42A
- I / O expansion card 4 DC inputs and 2 outputs
- the ability to assign functions to inputs and outputs depending on the inverter settings
- inputs can be switched via an external or internal 24 VDC power supply
- possibility to switch with J1 jumper between SINK and SOURCE
- maximum load of the 48VDC 50 mA output
EMC-D611
- I / O expansion card 6 AC inputs
- the possibility of assigning functions to inputs depending on the inverter settings
- 100 - 130 VAC input signal with a frequency of 47-63 Hz
- input ON time 10 ms, OFF time 20 ms
Communication cards
EMC-COP01
CANopen card
- RJ45 interface
- CAN data transmission method
- Baud rate 1M 500k 250k 125k 100k 50k
- Supports CANopen protocols
CMC-EIP01
Ethernet IP and Modbus TCP card
- RJ45 interface with Auto MDI / MDIX
- Transmission speed 10/100 Mbps
- Supports ICMP, IP, TCP, UDP, DHCP, HTTP, SMTP, MODBUS OVER TCP / IP, EtherNet / IP, Delta Configuration protocols
- Configuration with inverter parameters or via Ethernet
CMC-MOD01
Modbus TCP card
- RJ45 interface with Auto MDI / MDIX
- Transmission speed 10/100 Mbps
- Supports ICMP, IP, TCP, UDP, DHCP, HTTP, SMTP, MODBUS OVER TCP / IP protocols,